Communications Copper Cables
A complete portfolio for underground, aerial and central office solutions.
The widest range of capacity options from 10 to 2400 pairs.
Designed to meet all main international specifications.
Guaranteed solutions from a world-class vendor. |
Download the brochure
(327 KB)
|
|
|
|
|
|
|
|
|
|
|
|
|
Underground - Buried 1
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if specified)
Moisture barrier: Aluminium polylaminated tape
Sheath: PE
Armouring: Helical steel tapes
Outer sheath: PE, PVC
|
|
|
|
|
|
|
|
|
|
|
|
Underground - Buried 2
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if specified)
Moisture barrier: Aluminium polylaminated tape
Sheath: PE
Armouring: Corrugated steel tapes
Outer sheath: PE, PVC |
|
|
|
|
|
|
|
|
|
|
|
Underground - Buried 3
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if specified)
Moisture barrier: Aluminium polylaminated tape
Sheath: PE
Armouring: Steel wires
Outer sheath PE, PVC
|
|
|
|
|
|
|
|
|
|
|
|
Underground - In Duct
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 2400 pairs
Water penetration: Filling compound
(if specified)
Moisture barrier: Aluminium polylaminated tape
Sheath: PE
|
|
|
|
|
|
|
|
|
|
|
|
Aerial - Figure 8
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 200 pairs
Water penetration: Filling compound
(if specified)
Screen/moisture barrier: Wrapped aluminium tapes Aluminium polylaminated tape
Sheath: PE
Supporting cord: Steel wires |
|
|
|
|
|
|
|
|
|
|
|
Aerial - Circular
Conductor: Plain copper 0.4 to 0.9 mm
Insulation: Solid, foam-skin, cellular PE
Cabling: Pair or quad; unit and sub-unit
Size: 10 to 200 pairs
Water penetration: Filling compound
(if specified)
Screen/moisture barrier: Wrapped aluminium tapes Aluminium polylaminated tape
Sheath: PE |
|
|
|
|
|
|
|
|
|
|
|
Aerial - Drop Wire
Conductor: Bronze 1mm
Insulation: Solid PE
Size: 1 pair
Sheath: PVC
|
|
|
|
|
|
|
|
|
|
|
|
Aerial - xDSL Drop
Conductor: Plain copper 0.6 mm
Insulation: Solid PE
Size: 2 to 4 pairs
Water penetration: Filling compound
(if specified)
Strength member: Aramid
Outer Sheath: PE
|
|
|
|
|
|
|
|
|
|
|
|
Indoor - Distribution
Conductor: Tinned copper 0.4 to 0.9 mm
Insulation: PVC
Cabling: Pair or quad; unit and sub-unit
Size: 1 to 400 pairs
Screen: Polyester plated aluminium tape
(if specified)
Sheath: PVC
|
|
|
|
|
|
|
|
|
|
|
|
Indoor - Jumper Wire
Conductor: Tinned copper 0.4 to 0.9 mm
Insulation: PVC
Size: 1 to 7 wires
|
|
|
|
|
|
|
|
|
|
|
|
Indoor - Subscriber Wire
Conductor: Copper 0.4 to 0.9 mm
Insulation: Solid PE
Size: 1 pair or 1 quad
Sheath: PVC (loose tube)
|
|
|
|
|
|
|
|
|
|
|
|
Indoor - xDSL Screened Cables
Conductor: Plain copper 0.4 to 0.5 mm
Insulation: Solid PE or foam skin PE
Cabling: Pair, unit of 4 or 24 pairs, bundles of 24 or 32 pairs
Size: Up to 96 or 128 pairs
Screen/Braid: Polyester plated AL tape and tinned copper wire braid
Outer sheath: Low Smoke Zero Halogen |
|
|
|
|
|
|
|